Analisis Perawatan Self Contained Breathing Apparatus di Bandar Udara Kualanamu

Authors

  • Harliansyah Hasibuan Politeknik Penerbangan Indonesia Curug
  • Tiara Nugrahayani Politeknik Penerbangan Indonesia Curug
  • Lina Rosmayanti Politeknik Penerbangan Indonesia Curug

DOI:

https://doi.org/10.51903/946eme54

Keywords:

Self Contained Breathing Apparatus, SCBA Maintenance, Kualanamu Airport, ARFF, Aviation Safety

Abstract

The Self-Contained Breathing Apparatus (SCBA) is a vital safety device used by Aircraft Rescue and Firefighting (ARFF) personnel during rescue and firefighting operations at the airport. This study aims to analyze the SCBA maintenance process to ensure equipment reliability and personnel safety at Kualanamu International Airport Medan. This research employs a qualitative descriptive method, with data collection techniques including direct observation, in-depth interviews, and field documentation conducted during the author’s On the Job Training (OJT) from October 2024 to February 2025. Research instruments such as interview guides and observation sheets were utilized to identify weaknesses in the SCBA maintenance system. The results reveal that the SCBA maintenance process is not yet optimal, as indicated by the absence of a specific checklist and standardized inspection procedures for each SCBA component. Furthermore, the location of the clean air refill compressor, which is placed near the vehicle parking area, poses a risk of air contamination within the SCBA cylinders. Additionally, the number of available SCBA units does not meet the minimum standards stipulated in Regulation PR 30 of 2022. The proposed solutions in this study include the development of a standardized inspection logbook, procurement of SCBA units with uniform specifications, and the construction of a dedicated room for compressor placement.

References

[1] D. Hostler and D. R. Pendergast, “Respiratory responses during exercise in self-contained breathing apparatus among firefighters and non-firefighters,” Safety and Health at Work, vol. 9, no. 4, pp. 468–472, 2018, doi: 10.1016/j.shaw.2018.02.002.

[2] S. J. Kim and S. Ham, “Evaluation of air quality inside self-contained breathing apparatus used by firefighters,” Fire, vol. 6, no. 347, pp. 1–19, 2023, doi: 10.3390/fire6090347.

[3] R. M. Duffy and W. M. Lambert, “NFPA 1989,” National Fire Protection Association, 2003.

[4] S. Ramezanifar, Z. Shakiba, E. A. Pirposhteh, M. Poursadeghiyan, and A. S. Sahlabadi, “The effects of personal protective equipment on heart rate, oxygen consumption and body temperature of firefighters: A systematic review,” Work, vol. 76, pp. 95–107, 2023, doi: 10.3233/WOR-220121.

[5] National Fire Protection Association, NFPA 1989: Standard on breathing air quality for emergency services respiratory protection. Quincy, MA: NFPA, 2019.

[6] National Fire Protection Association, NFPA 1852: Standard on selection, care, and maintenance of open-circuit self-contained breathing apparatus (SCBA). Quincy, MA: NFPA, 2019.

[7] M. Mazza, “Firefighter self-contained breathing apparatus: A review of the literature,” Occupational Health and Safety, pp. 1–18, 2008.

[8] Y. Li, J. Wang, and H. Zhao, “Toxic gas exposure in fire environments,” Process Safety and Environmental Protection, vol. 165, pp. 159–169, 2022, doi: 10.1016/j.psep.2022.07.008.

[9] National Institute for Occupational Safety and Health (NIOSH), Self-contained breathing apparatus (SCBA) information. Washington, DC: U.S. Department of Health & Human Services, 2021.

[10] N. Nugraha, R. Santosa, and A. S. Pradana, “Penggunaan SCBA dalam operasi penyelamatan di bandara,” Jurnal Keselamatan Transportasi Udara, vol. 4, no. 2, pp. 45–52, 2021.

[11] G. Martadinata, H. Santoso, and I. Prasetyo, “Evaluasi kesiapan peralatan pemadam kebakaran di bandara,” Jurnal Transportasi Udara, vol. 3, no. 1, pp. 12–20, 2021.

[12] Watertown Fire Department, SCBA Maintenance Manual. Watertown: WFD, 2021.

[13] OSHA, Respiratory protection standard. Washington, DC: Occupational Safety and Health Administration, 2021.

[14] Sugiyono, Metode Penelitian Kualitatif, Kuantitatif, dan R&D. Bandung: Alfabeta, 2023.

Published

2025-10-23

How to Cite

Analisis Perawatan Self Contained Breathing Apparatus di Bandar Udara Kualanamu. (2025). MANAJEMEN, 5(2), 272-280. https://doi.org/10.51903/946eme54